Product Model:MOD1002-MBus
Function Description:
MOD1002-MBus gateway can convert MBus to Modbus, with 1 Ethernet Port, 2 RS485 Port. Connect 4-Wire MBus meter to WinCC, Citect, IFIX, RSVIEW, KingView, ForceControl and other configuration software. Supported devices include MBus water meter, MBus energy meter, MBus heat meter, and Modbus devices.
This product is to replace the original XR1005-MBUS concentrator with a Modbus gateway. After the MBus concentrator and gateway functions are integrated, there is no need to install two devices, which is convenient for customers to wire, saves installation space, and saves costs.
The gateway is configured using X2Modbus software. The "X" of X2Modbus represents various collection protocols, "2" is a homophone of "To" indicating conversion, and "Modbus" ultimately supports standard Modbus RTU/TCP.
Users can configure the project according to the field device point table and forward it to a standard Modbus RTU slave or Modbus TCP server. When uploaded to the hardware gateway, Modbus clients can access data from field devices through the gateway.
Note: The Modbus register base address at the gateway collection end starts from 1 (Base1), and the hexadecimal address starts from 0 (Base0); the Modbus register base address at the forwarding end starts from 1 (Base1).
Collection Model:
1¡¢MBus_WaterMeter 2¡¢MBus_EnergyMeter 3¡¢MBus_EnergyMeter_EN 4¡¢ModbusRTUClient 5¡¢ModbusTCPClient 6¡¢DL/T645-1997/2007 7¡¢Simulator
Note:
1. 4-wire MBus device can be connected to COM1 and COM2. The A+ and B - terminals have a voltage within 5V.
2. Connecting them in reverse can burn the gateway or meter, and any consequences caused by wiring issues are the responsibility of the customer Undertake.
3. COM1 and COM2 are standard RS485 ports that can be used to connect devices with Modbus RTU protocol, while the Ethernet port can connect devices with Modbus TCP protocol. 4. Customers encounter non-standard MBus protocols that support paid custom development, which can generally be completed within 2 weeks.
Runtime environment:
OS£º Win7¡¢Win8¡¢Win10¡¢ Win11¡¢Win Server 2008¡¢Win Server 2016
The hardware gateway comes with a built-in web server that supports browsers such as Google Chrome, Microsoft Edge, Apple Safari, Firefox, Opera, and 360 Speed Mode.
Register Type&Num
The number of gateway registers is dynamically supported, and 512 points can be built for each
Modbus Register Type |
Modbus Register Number |
0X(Coil Status, R&W) |
512 |
1X(Input Status,Read Only ) |
512 |
4X(Holding Register, R&W) |
512 |
3X(Input Register, Read Only) |
512 |
Software Features£º |
- Green and free installation, support both Chinese and English; - Support MBus_WaterMeter(CJ188)¡¢MBus_EnergyMeter(CJ188)¡¢ MBus_EnergyMeter_EN¡¢ModbusRTUClient¡¢ModbusTCPClient¡¢ DLT645-1997¡¢DLT645-2007 to Modbus RTU/TCP; |
- S upport four types of register: 0X, 1X, 3X, and 4X; |
- Support multiple Modbus slave; |
- Support JavaScript and Trigger to realize logic control; |
- Support for linear transformation, location, and high and low byte conversion; |
- Support internal variable function, and check the communication status; |
- Support Web browsing and check real-time data; - X 2Modbus software is easy configuration, with 512 points configurable within 15minutes. |
|
|
|
 |
|
|
Application Principle Diagram

|
|
|
Product Dimensions

If you need to develop a non-standard protocol , please contact us.
If it is best to express the device to our company, the development cycle is usually 2 weeks.